SPRTechnote

SPR # CPRE5JBS5T fixed in 6.0.5 releaseRecommended Release (14.0 FP1)

Product Area: Domino Offline Services Technical Area: Domino Offline Services Platform: Win 2000; Win NT


SPR# CPRE5JBS5T - A large QuickPlace configuration (very large number of rooms (ie, databases)) was causing the following DOLS error when syncing the application the first time: "Error synchronizing offline application". The DOLS buffer that reads the configuration (number of rooms) was not large enough (original size of buffer was 2000 bytes). The fix was to increase the buffer size to 32*1024 to accomodate large Quickplace configurations. Customers with a Quickplace configuration that includes the "number of rooms", (this is a text list) exceeding 2000 bytes, will run into this problem without the fix.


Last Modified on 12/04/2013