Explanation:
Use this setting to control whether OLE objects launch in place, or
externally in the
object's native application. This setting applies to: either client
configuration. This
setting overrides any of the other OLE related INI variables.
0 or not present (default) - Default OLE editing behavior occurs. Default
behavior in the
Standard Configuration client is to launch OLE applications externally;
current default
behavior in the Basic Configuration client is to launch applications
in-place for OLE
1 - Disables all in-place editing, and OLE objects are launched
externally in their native application
Note: Setting this variable to 0 does not enable in-place editing
in the Standard
Configuration client. To enable In-place editing on the Standard
Configuration client use one
of the settings listed below. For more information on these settings, see
the specific
notes.ini setting. For example:
Ole.InPlace.Excel.Sheet = 1
Ole.InPlace.Excel.Sheet = 1
Ole.InPlace.PBrush = 1
Ole.InPlace.PowerPoint.Show = 1
Ole.InPlace.Word.Document = 1
Ole.InPlace.Lotus123.Workbook = 1
Ole.InPlace.WordPro.Document = 1
Applies to:
Clients
Default Value:
0
UI Equivalent:
None
Syntax:
Ole.InPlace.Disable = value
|